Journal cover Journal topic
Atmospheric Chemistry and Physics An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

IF value: 5.414
IF5.414
IF 5-year value: 5.958
IF 5-year
5.958
CiteScore value: 9.7
CiteScore
9.7
SNIP value: 1.517
SNIP1.517
IPP value: 5.61
IPP5.61
SJR value: 2.601
SJR2.601
Scimago H <br class='widget-line-break'>index value: 191
Scimago H
index
191
h5-index value: 89
h5-index89
Volume 3, issue 1
Atmos. Chem. Phys., 3, 67–72, 2003
https://doi.org/10.5194/acp-3-67-2003
© Author(s) 2003. This work is licensed under
the Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.
Atmos. Chem. Phys., 3, 67–72, 2003
https://doi.org/10.5194/acp-3-67-2003
© Author(s) 2003. This work is licensed under
the Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.

  03 Feb 2003

03 Feb 2003

Ground-based intercomparison of two isoprene measurement techniques

E. Leibrock*,2,1, L. G. Huey3, P. D. Goldan2,1, W. C. Kuster2,1, E. Williams2,1, and F. C. Fehsenfeld2,1 E. Leibrock et al.
  • 1Aeronomy Laboratory, Environmental Research Laboratories, NOAA, Boulder, Colorado, USA
  • 2Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, Colorado, USA
  • 3School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, Georgia, USA
  • *present address: The Boston Consulting Group, Ludwigstraße 21, D–80539 München, Germany

Abstract. An informal intercomparison of two isoprene (C5H8) measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS) was compared to a well-established gas chromatographic technique (GC). The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

Publications Copernicus
Download
Citation
Altmetrics
Final-revised paper
Preprint