<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0"><?xmltex \makeatother\@nolinetrue\makeatletter?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">ACP</journal-id><journal-title-group>
    <journal-title>Atmospheric Chemistry and Physics</journal-title>
    <abbrev-journal-title abbrev-type="publisher">ACP</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Chem. Phys.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1680-7324</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/acp-20-13241-2020</article-id><title-group><article-title>Spatial and temporal representativeness of point measurements for nitrogen dioxide pollution levels in cities</article-title><alt-title>Spatial and temporal representativeness of point measurements</alt-title>
      </title-group><?xmltex \runningtitle{Spatial and temporal representativeness of point measurements}?><?xmltex \runningauthor{Y.~Zhu et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1 aff2">
          <name><surname>Zhu</surname><given-names>Ying</given-names></name>
          <email>ying.zhu@physik.uni-muenchen.de</email>
        </contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff2">
          <name><surname>Chen</surname><given-names>Jia</given-names></name>
          <email>jia.chen@tum.de</email>
        <ext-link>https://orcid.org/0000-0002-6350-6610</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Bi</surname><given-names>Xiao</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2733-0451</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Kuhlmann</surname><given-names>Gerrit</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-7021-4712</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Chan</surname><given-names>Ka Lok</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Dietrich</surname><given-names>Florian</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3069-9946</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Brunner</surname><given-names>Dominik</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-4007-6902</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Ye</surname><given-names>Sheng</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1011-7486</ext-link></contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Wenig</surname><given-names>Mark</given-names></name>
          <email>mark.wenig@lmu.de</email>
        </contrib>
        <aff id="aff1"><label>1</label><institution>Meteorological Institute, Ludwig-Maximilians-Universität München, Munich, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>TUM Department of Electrical and Computer Engineering, Technische Universität München, Munich, Germany</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf, Switzerland</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Remote Sensing Technology Institute (IMF), German Aerospace Center (DLR), Oberpfaffenhofen, Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Ying Zhu (ying.zhu@physik.uni-muenchen.de), Mark Wenig (mark.wenig@lmu.de), and Jia Chen (jia.chen@tum.de)</corresp></author-notes><pub-date><day>10</day><month>November</month><year>2020</year></pub-date>
      
      <volume>20</volume>
      <issue>21</issue>
      <fpage>13241</fpage><lpage>13251</lpage>
      <history>
        <date date-type="received"><day>26</day><month>December</month><year>2019</year></date>
           <date date-type="rev-request"><day>9</day><month>March</month><year>2020</year></date>
           <date date-type="rev-recd"><day>24</day><month>July</month><year>2020</year></date>
           <date date-type="accepted"><day>24</day><month>August</month><year>2020</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2020 Ying Zhu et al.</copyright-statement>
        <copyright-year>2020</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020.html">This article is available from https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020.html</self-uri><self-uri xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020.pdf">The full text article is available as a PDF file from https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e178">In many cities around the world the overall air quality is improving, but at the same time nitrogen dioxide (<inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) trends show stagnating values and in many cases could not be reduced below air quality standards recommended by the World Health Organization (WHO). Many large cities have built monitoring stations to continuously measure different air pollutants. While most stations follow defined rules in terms of measurement height and distance to traffic emissions, the question remains of how representative are those point measurements for the city-wide air quality. The question of the spatial coverage of a point measurement is important because it defines the area of influence and coverage of monitoring networks, determines how to assimilate monitoring data into model simulations or compare to satellite data with a coarser resolution, and is essential to assess the impact of the acquired data on public health.</p>
    <p id="d1e192">In order to answer this question, we combined different measurement data sets consisting of path-averaging remote sensing data and in situ point measurements in stationary and mobile setups from a measurement campaign that took place in Munich, Germany, in June and July 2016. We developed an algorithm to strip temporal from spatial patterns in order to construct a consistent <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> pollution map for Munich. Continuous long-path differential optical absorption spectroscopy (LP DOAS) measurements were complemented with mobile cavity-enhanced (CE) DOAS, chemiluminescence (CL) and cavity attenuated phase shift (CAPS) instruments and were compared to monitoring stations and satellite data. In order to generate a consistent composite map, the LP DOAS diurnal cycle has been used to normalize for the time of the day dependency of the source patterns, so that spatial and temporal patterns can be analyzed separately. The resulting concentration map visualizes pollution hot spots at traffic junctions and tunnel exits in Munich, providing insights into the strong spatial variations. On the other hand, this database is beneficial to the urban planning and the design of control measures of environment pollution. Directly comparing on-street mobile measurements in the vicinity of monitoring stations resulted in a difference of 48 %. For the extrapolation of the monitoring station data to street level, we determined the influence of the measuring height and distance to the street. We found that a measuring height of 4 m, at which the Munich monitoring stations measure, results in 16 % lower average concentrations than a measuring height of 1.5 m, which is the height of the inlet of our mobile measurements and a typical pedestrian breathing height. The horizontal distance of most stations to the center of the street of about 6 m also results in an average reduction of 13 % compared to street level concentration. A difference of 21 % in the <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations remained, which could be an indication that city-wide measurements are needed for capturing the full range and variability of concentrations for assessing pollutant exposure and air quality in cities.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<?pagebreak page13242?><sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e226">Many former studies <xref ref-type="bibr" rid="bib1.bibx20 bib1.bibx11 bib1.bibx21" id="paren.1"/> have been pointed out that <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is an important composition in the process of both tropospheric and stratospheric chemistry. It is one of the major pollution products from combustion processes. Catalytic formation of tropospheric ozone (<inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and the formation of secondary aerosols that cause acid rain, all of which involve its participation. Elevated concentration of atmospheric <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is acknowledged to be noxious to human beings' health. In urban environments, exhaust emissions are one of the primary sources of air pollution, particularly <inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M8" display="inline"><mml:mo lspace="0mm">=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">NO</mml:mi><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). Nitrogen monoxide (NO) accounts for the majority of direct traffic emissions, which is subsequently oxidized to form <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> although some <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is emitted directly <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx16 bib1.bibx26" id="paren.2"/>. <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> levels are often strongly correlated with many other toxic air pollutants <xref ref-type="bibr" rid="bib1.bibx32 bib1.bibx51 bib1.bibx50" id="paren.3"/>. Its concentration can be easily and precisely measured, which is helpful in assessing general air quality. Since it is a short-lived compound gas from numerous different sources, its concentrations can vary strongly, both in space and time.</p>
      <p id="d1e339">According to the 2017 European Environment Agency report <xref ref-type="bibr" rid="bib1.bibx12" id="paren.4"/>, some <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations measured at air quality monitoring stations are above the World Health Organization (WHO) Air Quality Guideline (AQG) values of 200 <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M15" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>  (hourly) and 40 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M17" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (annually). A total of 10.5 % of the stations across European cities exceeded the annual limits, including several German cities. None of the exceedances were observed at rural background stations but instead in urban or suburban stations. More specifically, 89 % of the exceeded values were observed at traffic stations. The 2016 air quality report by the German Environment Agency (Umweltbundesamt) <xref ref-type="bibr" rid="bib1.bibx39" id="paren.5"/> also pointed out that the air pollution in urban conurbations was primarily affected by traffic. In the 2015 technical report by the Bavarian environment agency (Landesamt für Umwelt, LfU) <xref ref-type="bibr" rid="bib1.bibx30" id="paren.6"/>, the on-road <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration limits were exceeded in most Bavarian cities from 2000 to 2014. In particular, the annual <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> level in Munich measured at Landshuter Allee station was more than twice the annual <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> limit value of the WHO AQG of 40 <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M22" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.</p>
      <p id="d1e457">With a growing focus on air pollution in the public attention, stationary monitoring networks have been established all over the world. Related regulations also have been certified. For example, in Europe, the European directive 2008/50/EC lists a number of criteria for microscale positioning of air quality measurements (Annex III section C). Monitoring stations in the EU continuously measure different pollutants, and while most stations follow the defined rules in terms of measurement height and distance to traffic emissions, the question remains of how representative are those point measurements for the city-wide air quality. According to a study of the spatial distribution of <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in Hong Kong <xref ref-type="bibr" rid="bib1.bibx52" id="paren.7"/>, large differences between mobile measurements around the city and seven local monitoring stations were observed. In order to determine the representativeness of air quality monitoring stations, different measurement methods have to be combined. Most monitoring stations utilize the chemiluminescence (CL) technique for <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurements. Thereby the <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration is determined indirectly by calculating the difference between <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and NO concentrations. The concentration of oxidized odd-Nitrogen species (<inline-formula><mml:math id="M27" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>y</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) is inevitably included as a small measurement error. Nevertheless, the CL technique has a good detection sensitivity that is given by its low background signal. This is because for initiating the fluorescence no light source is required <xref ref-type="bibr" rid="bib1.bibx11" id="paren.8"/>. In this study, we compared our CL and cavity-enhanced DOAS (CE DOAS) data to the local air quality stations and studied the diffusion rate of <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in both vertical and horizontal directions from one of the stations.</p>
      <p id="d1e533">For our study we utilized a combination of a long-path DOAS (LP DOAS) instrument and a CE DOAS, as well as a cavity attenuated phase shift spectroscopy (CAPS) instrument to determine the spatiotemporal variability of <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations in the central area of Munich. CE DOAS is a spectroscopic measurement technique that uses an optical resonator to fold  the absorption path into a resonator <xref ref-type="bibr" rid="bib1.bibx52 bib1.bibx33 bib1.bibx38 bib1.bibx35 bib1.bibx46 bib1.bibx42 bib1.bibx29" id="paren.9"/>. CAPS <xref ref-type="bibr" rid="bib1.bibx17" id="paren.10"/> is a spectroscopic detection technology, generally referred to as cavity-enhanced optical absorption, which has also been applied for the detection of atmospheric pollutants in many studies <xref ref-type="bibr" rid="bib1.bibx49 bib1.bibx28 bib1.bibx15 bib1.bibx23 bib1.bibx25" id="paren.11"/>. The advantage of CE DOAS and CAPS is the fact that they are not sensitive to other reactive nitrogen oxides in the atmosphere like some other in situ <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> monitoring techniques. They are both characterized by a compact setup and have no sensitivity loss during the operation. For mobile measurements a fast sampling rate is necessary, and the high accuracy of the instruments allowed a sampling rate of 2 s. Similar instrument setups have been used in many on-road studies of vehicles emissions <xref ref-type="bibr" rid="bib1.bibx52 bib1.bibx6 bib1.bibx36 bib1.bibx34 bib1.bibx40 bib1.bibx44" id="paren.12"/>.</p>
      <p id="d1e572">For our study we conducted on-road measurements of <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations in June and July 2016 in order to investigate street level air quality and locate emission hot spot areas. Additionally, LP DOAS measurements were conducted to observe the temporal variability of ambient <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in Munich. A measurement system consisting of several DOAS instruments was continuously operational for over 2 years (see Sect. <xref ref-type="sec" rid="Ch1.S2"/>). The algorithm that combines the mobile and stationary measurement data is described in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1.SSS1"/>. The resulting on-road <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> spatial patterns are presented in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1.SSS2"/>. The CE DOAS and CL were set up next to the Bavarian LfU<?pagebreak page13243?> local air quality station to measure the horizontal and vertical <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> distributions, and the results are shown in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>. <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> data from the Ozone Monitoring Instrument (OMI) on board the NASA Aura satellite were used to verify how the LP DOAS measurements compare to the much larger OMI ground pixels covering a larger fraction of the city in order to find out whether the LP DOAS measurements are representative for the whole city. Detailed analysis is provided in the Supplement.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Methodology</title>
      <p id="d1e647">This study combines different measurement methods such as mobile, stationary and satellite measurements to answer the question of how representative sparse point measurements are to determine the air quality of a city. Furthermore, we want to find out what kind of measurement approach is needed to determine the overall air quality in a city. The Munich three-dimensional DOAS measuring system combines three different types of DOAS instruments, specifically, CE DOAS and LP DOAS. The measurement system is installed on the roof of the building of the Meteorological Institute Munich (MIM) at the Ludwig Maximilians University (LMU) in the center of Munich. The three LP DOAS instruments scan retroreflector arrays in different directions and distances, capturing the horizontal variations at the rooftop level. A CE DOAS is used to determine the <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> variability on the ground. The LP DOAS instruments run continuously, whereas the CE DOAS is used at different times of the year/week/day under varying meteorological conditions to determine street level <inline-formula><mml:math id="M37" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> distributions.</p>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Mobile measurements</title>
      <p id="d1e679">A CE DOAS and a CAPS instruments in two vehicles were used for on-street sampling of traffic emissions. The sampling inlets were located at the front right window of each vehicle at 1.5 m height. For measurements in Munich's city park (English Garden), we used a bike trailer. The measurements were performed on two days in March, three days in May, five days in June and six days in July 2016 to cover a large part of the urban area in Munich. Table <xref ref-type="table" rid="Ch1.T1"/> shows the dates, measurement times and number of measurements for all measurement days. The sample resolutions of the CE DOAS and the CAPS were both adjusted to 2 s during the mobile measurements. The measurements were performed on varying routes during daytime to cover the entire city center area. All measurements were spatially averaged to a high-resolution grid of 20 m <inline-formula><mml:math id="M38" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 20 m. This resolution has been chosen according to an average driving speed of 40–50 km h<inline-formula><mml:math id="M39" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and the measurement sampling time of 2 s, so that at least one measurement value per drive-by falls into each grid box. All measurements from different drives and different days are averaged for each grid cell after diurnal cycle normalization.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e706">Overview of the measurement days, time and number of measurements.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Measurement date</oasis:entry>
         <oasis:entry colname="col2">Measurement time</oasis:entry>
         <oasis:entry colname="col3">Number</oasis:entry>
         <oasis:entry colname="col4">Measurement date</oasis:entry>
         <oasis:entry colname="col5">Measurement time</oasis:entry>
         <oasis:entry colname="col6">Number</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(yyyy.mm.dd)</oasis:entry>
         <oasis:entry colname="col2">(hours)</oasis:entry>
         <oasis:entry colname="col3">of measurements</oasis:entry>
         <oasis:entry colname="col4">(yyyy.mm.dd)</oasis:entry>
         <oasis:entry colname="col5">(hours)</oasis:entry>
         <oasis:entry colname="col6">of measurements</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">2016.03.21</oasis:entry>
         <oasis:entry colname="col2">3.84</oasis:entry>
         <oasis:entry colname="col3">5313</oasis:entry>
         <oasis:entry colname="col4">2016.06.16</oasis:entry>
         <oasis:entry colname="col5">5.48</oasis:entry>
         <oasis:entry colname="col6">7586</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2016.03.22</oasis:entry>
         <oasis:entry colname="col2">1.82</oasis:entry>
         <oasis:entry colname="col3">2523</oasis:entry>
         <oasis:entry colname="col4">2016.06.17</oasis:entry>
         <oasis:entry colname="col5">2.75</oasis:entry>
         <oasis:entry colname="col6">3804</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2016.05.09</oasis:entry>
         <oasis:entry colname="col2">2.29</oasis:entry>
         <oasis:entry colname="col3">3172</oasis:entry>
         <oasis:entry colname="col4">2016.07.01</oasis:entry>
         <oasis:entry colname="col5">2.86</oasis:entry>
         <oasis:entry colname="col6">3955</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2016.05.10</oasis:entry>
         <oasis:entry colname="col2">3.62</oasis:entry>
         <oasis:entry colname="col3">5019</oasis:entry>
         <oasis:entry colname="col4">2016.07.06</oasis:entry>
         <oasis:entry colname="col5">6.24</oasis:entry>
         <oasis:entry colname="col6">17 292</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2016.05.11</oasis:entry>
         <oasis:entry colname="col2">4.55</oasis:entry>
         <oasis:entry colname="col3">6295</oasis:entry>
         <oasis:entry colname="col4">2016.07.07</oasis:entry>
         <oasis:entry colname="col5">10.29</oasis:entry>
         <oasis:entry colname="col6">28 489</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2016.06.06</oasis:entry>
         <oasis:entry colname="col2">3.38</oasis:entry>
         <oasis:entry colname="col3">4674</oasis:entry>
         <oasis:entry colname="col4">2016.07.08</oasis:entry>
         <oasis:entry colname="col5">5.22</oasis:entry>
         <oasis:entry colname="col6">14 466</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2016.06.07</oasis:entry>
         <oasis:entry colname="col2">4.66</oasis:entry>
         <oasis:entry colname="col3">6454</oasis:entry>
         <oasis:entry colname="col4">2016.07.11</oasis:entry>
         <oasis:entry colname="col5">5.1</oasis:entry>
         <oasis:entry colname="col6">14 123</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">2016.06.13</oasis:entry>
         <oasis:entry colname="col2">4.25</oasis:entry>
         <oasis:entry colname="col3">5882</oasis:entry>
         <oasis:entry colname="col4">2016.07.13</oasis:entry>
         <oasis:entry colname="col5">2.48</oasis:entry>
         <oasis:entry colname="col6">2976</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">Total</oasis:entry>
         <oasis:entry colname="col5">64.8</oasis:entry>
         <oasis:entry colname="col6">126440</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e997">The CE DOAS is composed of an air sampling system, an optical resonator with two highly reflective mirrors, a blue LED light source and a spectrometer <xref ref-type="bibr" rid="bib1.bibx35" id="paren.13"/>. For the spectral retrieval in the wavelength range 435.6  to 455.1 nm, we used DOASIS <xref ref-type="bibr" rid="bib1.bibx27" id="paren.14"/>. The <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> reference absorption cross is from <xref ref-type="bibr" rid="bib1.bibx41" id="text.15"/>, <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> from <xref ref-type="bibr" rid="bib1.bibx18" id="text.16"/>, <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> from <xref ref-type="bibr" rid="bib1.bibx37" id="text.17"/> and CHOCHO (glyoxal) from <xref ref-type="bibr" rid="bib1.bibx45" id="text.18"/>.</p>
      <p id="d1e1055">The CAPS measurement technique is closely related to cavity ring-down laser absorption spectroscopy (CRDS), which determines the concentration of trace gases from the decay rate of the light source in the optical resonator <xref ref-type="bibr" rid="bib1.bibx2 bib1.bibx5 bib1.bibx4 bib1.bibx13" id="paren.19"/>. CRDS is a laser-based system, while CAPS uses an incoherent light source (a blue LED) that is well matched to the <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption band. The CAPS <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> system mainly consists of a blue LED, a measurement chamber with two highly reflective mirrors centered at 450 nm and a vacuum photodiode detector. It estimates the <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration by directly measuring the optical absorption of <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at the 450 nm wavelength within the electromagnetic spectrum. The light appears as a distorted waveform after passing through two mirrors and the measurement cell, which is characterized by a phase shift that is determined by demodulation techniques in comparison to the initial LED light modulation. The phase shift is proportional to the absorbance of the light by the presence of <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. The concentration of <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> can be derived by measuring the amount of the phase shift. The detailed principles of the CAPS system are demonstrated in <xref ref-type="bibr" rid="bib1.bibx24 bib1.bibx25" id="text.20"/>.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Long-path (LP) DOAS observations</title>
      <p id="d1e1139">Three LP DOAS instruments were installed on the roof of the MIM. The measurement setups are displayed in Fig. <xref ref-type="fig" rid="Ch1.F1"/>. The measurement system started operation in December 2015 with a total absorption path of 3828 m across the English Garden to a retroreflector array located on the rooftop of the Hilton hotel building at <inline-formula><mml:math id="M49" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 48 m height. In January 2017 another absorption path of 1142 m was installed covering three blocks around the university area to a retroreflector at the St. Ludwig church in Munich at <inline-formula><mml:math id="M50" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 40 m above ground. Since July 2015 a retroreflector has also been installed at the roof of the N5 building of the Technical University of Munich (TUM) at <inline-formula><mml:math id="M51" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 28 m height, allowing an absorption path of 828 m. From July 2016 to August 2017 a path of 816 m to the roof of the building of the physics department of LMU at <inline-formula><mml:math id="M52" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 24 m height was operational as well. For the long-term average diurnal cycle calculation described in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1.SSS1"/> all available data from all measurement paths were used. LP DOAS measurements of light paths towards to the Hilton hotel, TUM and the LMU physics department were used to normalize the mobile measurements regarding the diurnal cycle. The measurement paths cover the university campus, the public park, residential areas and areas with heavy traffic.<?pagebreak page13244?> The instrumental background was corrected by subtracting the LED reference spectra, including dark current, offset and background, from each measured spectrum.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e1177">Map of Munich city center and four optical paths of three LP DOAS instruments. Map data © Google Maps.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020-f01.png"/>

        </fig>

      <p id="d1e1186">A measurement sequence starts by taking a LED reference spectra using a shortcut system consisting of a diffuser plate in front of the y fiber and an exposure time of 10 s. Then a shutter is used to block the LED for measuring the atmospheric background spectrum for 1 s. Afterwards, the atmospheric spectrum with a maximum of 10 scans is taken. Each scan of a spectrum has a peak intensity of about 60 %–80 % saturation of the detector and typically requires 60–1000 ms, depending on the visibility and instrument setup. The total sampling time (the product of the number of scans and exposure time for each scan) was limited to 60 s. A full measurement sequence took between 30  and 90 s, depending on visibility conditions.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Local air quality monitoring network</title>
      <p id="d1e1197">The Bavarian LfU is operating five monitoring stations: three roadside stations at  Landshuter Allee, Stachus and Lothstraße (locations of the three stations are also presented in Fig. <xref ref-type="fig" rid="Ch1.F4"/>c), and two ambient stations in Allach and Johanneskirchen. In these stations the air pollutants NO, <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, CO, <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, PM<inline-formula><mml:math id="M55" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>, and PM<inline-formula><mml:math id="M56" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula> and in addition meteorological parameters such as relative humidity and temperature are measured. In this study we concentrated on the NO and <inline-formula><mml:math id="M57" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations that are continuously monitored using an in situ CL <inline-formula><mml:math id="M58" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> analyzer (HORIBA APNA-370) <xref ref-type="bibr" rid="bib1.bibx31" id="paren.21"/>.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><?xmltex \opttitle{{$\protect\chem{NO_{2}}$} concentration maps constructed using mobile measurements}?><title><inline-formula><mml:math id="M59" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration maps constructed using mobile measurements</title>
      <p id="d1e1295">The mobile measurement data can be used to create a map showing the city-wide distribution of air quality using <inline-formula><mml:math id="M60" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations as a general indicator (Fig. <xref ref-type="fig" rid="Ch1.F4"/>). As a first test, we compared the averaged measurement values within a 10 km radius around the three governmental monitoring stations at Landshuter Allee, Lothstraße, and Stachus and obtained an averaged concentration of 93 <inline-formula><mml:math id="M61" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M62" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the mobile measurements and 48 <inline-formula><mml:math id="M63" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M64" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the three stations for the campaign days in June and July 2016. The large difference can be explained by looking at the criteria for the location of monitoring sites set by the European Union: the recommended measurement height is between 1.5  and 4 m; maximum distance to the street is 10 m and at a minimum distance to the next crossroad of 25 m <xref ref-type="bibr" rid="bib1.bibx10" id="paren.22"/>. Most monitoring stations have the inlet positioned at 4 m height. The mobile measurement data, however, include the significantly increased concentrations at crossroads, tunnel exits and other pollution hot spots. In addition, the height of the measurement inlets differs by 2.5 m between the mobile measurements and the governmental monitoring stations, which also influences the comparison. In order to determine how representative point measurements are for the city-wide air quality, we analyzed the correlation between point measurements and the distribution captured by mobile measurements, between point and path-averaging measurements, as well as between path-averaging and satellite measurements. Since the spatial distribution can not be captured instantaneously, an algorithm to normalize for the diurnal variation is needed in order to create a consistent map representing only the<?pagebreak page13245?> spatial variability of daily average concentrations instead of temporal influences.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e1357">Normalization curve used to correct mobile measurement data. The purple curve is the long-term average diurnal pattern for the day of the week of the measurement day (Monday in this example), which is fitted (scaling with the linearly time dependent factor and offset) to the measurement data of 13 June 2016 shown in green, excluding the data outside of the 2<inline-formula><mml:math id="M65" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> area shown in gray. The resulting cyan curve is used to remove the diurnal dependency of the mobile measurements data.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020-f02.png"/>

        </fig>

<sec id="Ch1.S3.SS1.SSS1">
  <label>3.1.1</label><title>Normalization of the diurnal cycle</title>
      <p id="d1e1380">As a mobile survey cannot capture the concentrations at different locations simultaneously, and the <inline-formula><mml:math id="M66" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements are naturally influenced by daily variations such as changing boundary layer height or the diurnal cycle of the traffic amount, we use an algorithm to separate temporal and spatial patterns in the data set.</p>
      <p id="d1e1394">First, the algorithm normalizes the long time series of LP DOAS measurements of atmospheric <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> by dividing through the daily average <inline-formula><mml:math id="M68" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration of the same day. The mean concentration curves for each day of the week over a period of 2.5 years are calculated in order to obtain a relative diurnal <inline-formula><mml:math id="M69" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> variation pattern (purple curve in Fig. <xref ref-type="fig" rid="Ch1.F2"/>). The normalized averaged diurnal <inline-formula><mml:math id="M70" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> curve of the corresponding weekday is fitted (using an offset and a scaling with a linearly time dependent factor) to the normalized LP DOAS measurement of the corresponding day, coinciding with the mobile measurements. In order to remove the influence of outliers, <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> values outside of 2<inline-formula><mml:math id="M72" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> variation of the fitted curve are disregarded (cyan curve).
Fig. <xref ref-type="fig" rid="Ch1.F2"/> shows the fitting process for the normalization curve for one day of the measurement campaign. The other days show very similar characteristics with a significant peak in the morning and evening rush hours. Dividing the mobile measurement data by the curve data removes the diurnal dependencies and allows focusing on spatial pattern.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e1466">The distribution of the differences in between the inferred daily average concentrations and 24 h average concentrations measured by LfU stations. Bin width is 1 ppb. Evaluated stations including Allach, Johanneskirchen and Lothstraße.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020-f03.png"/>

          </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e1478"><bold>(a)</bold> CE DOAS and CAPS mobile measurements of <inline-formula><mml:math id="M73" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in Munich in 2016. <bold>(b)</bold> Normalized spatial distribution of <inline-formula><mml:math id="M74" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> using coinciding LP DOAS data to remove the diurnal dependencies. <bold>(c)</bold> Close-up of the city center. The three black diamonds in panel <bold>(c)</bold> are the locations of the governmental monitoring stations (Landshuter Allee, Lothstraße, Stachus). The area at the top right with very low concentrations represents the city park English Garden. Map data © Google Maps.</p></caption>
            <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020-f04.png"/>

          </fig>

      <p id="d1e1520">The corresponding stationary measurements from three LfU stations on mobile measurement days were used to evaluate the accuracy of the normalization algorithm. The inferred daily average concentration for each stationary measurement was retrieved based on the fitted LP DOAS normalization curve and then compared with the corresponding 24 h average concentration measured by the same station. The distribution of the concentration differences is shown in Fig. <xref ref-type="fig" rid="Ch1.F3"/>. The averaged difference is 0.7 ppb with 1<inline-formula><mml:math id="M75" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> uncertainty of 5.21 ppb. The inferred daily averages compared to the actual average concentrations at the stations Landshuter Allee and Stachus differ more because due to frequent traffic jams and stop-and-go traffic they show a different diurnal cycle. Overall, the normalization algorithm effectively separated the temporal and spatial influence for most mobile measurement locations.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e1535">Percentage of measured concentrations exceeding the WHO AQG 1 h guideline and its corrected on-road level thresholds for both temporal and spatial coverage. The values are broken down for before and after the normalization of the data according to diurnal patterns and also calculated for WHO guideline values adjusted for the different measurement height and distance to the street. </p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" namest="col2" nameend="col3" colsep="1">Percentage exceeding WHO guideline </oasis:entry>
         <oasis:entry rowsep="1" namest="col4" nameend="col5">Percentage exceeding adjusted WHO guideline </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Before normalization</oasis:entry>
         <oasis:entry colname="col3">After normalization</oasis:entry>
         <oasis:entry colname="col4">Before normalization</oasis:entry>
         <oasis:entry colname="col5">After normalization</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Temporally</oasis:entry>
         <oasis:entry colname="col2">4.4 %</oasis:entry>
         <oasis:entry colname="col3">14.5 %</oasis:entry>
         <oasis:entry colname="col4">1.7 %</oasis:entry>
         <oasis:entry colname="col5">6.7 %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Spatially (total)</oasis:entry>
         <oasis:entry colname="col2">4.1 %</oasis:entry>
         <oasis:entry colname="col3">17.1 %</oasis:entry>
         <oasis:entry colname="col4">1.1 %</oasis:entry>
         <oasis:entry colname="col5">4.6 %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Spatially (downtown)</oasis:entry>
         <oasis:entry colname="col2">5.5 %</oasis:entry>
         <oasis:entry colname="col3">12.4 %</oasis:entry>
         <oasis:entry colname="col4">1.6 %</oasis:entry>
         <oasis:entry colname="col5">4.7 %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e1644"><inline-formula><mml:math id="M76" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements at Karlsplatz (Stachus), Munich, with different heights above ground <bold>(a)</bold> and distances to the main street <bold>(b)</bold>. The ratio between 1 min averaged CE DOAS and coinciding CL measurements were calculated individually for the different heights and distances. Half-hour averaged CE DOAS measurements (blue curve) were compared with the corresponding CL measurements (red curve). Averaged ratios for different heights and distances (as defined in panel <bold>a</bold>) are shown in panel <bold>(c)</bold>; CE DOAS measurements at 1.5 m were averaged to 30 min intervals and compared with the half-hourly data of the governmental monitoring station at 4 m shown in panel <bold>(d)</bold>.</p></caption>
            <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://acp.copernicus.org/articles/20/13241/2020/acp-20-13241-2020-f05.png"/>

          </fig>

</sec>
<sec id="Ch1.S3.SS1.SSS2">
  <label>3.1.2</label><?xmltex \opttitle{Spatial distribution of {$\protect\chem{NO_{2}}$} in the city of Munich }?><title>Spatial distribution of <inline-formula><mml:math id="M77" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in the city of Munich </title>
      <p id="d1e1699">The measured concentrations during the campaign were spatially averaged to a high-resolution grid of 20 m <inline-formula><mml:math id="M78" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 20 m (Fig. <xref ref-type="fig" rid="Ch1.F4"/>a). Most of these measurements are distributed on major roads, including city, urban ring road, suburbs, rural areas and highways. Relatively high <inline-formula><mml:math id="M79" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> pollution could be observed on motorways and busy urban roads. A difference between main roads and adjoining side roads of up to a factor of 5 can be observed. A total of 4.4 % of the on-road measurements exceeded the WHO 1 h guideline value of 200 <inline-formula><mml:math id="M80" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>≈</mml:mo></mml:mrow></mml:math></inline-formula> 106 ppb (depending on temperature, here the appropriate conversion factor at 25 <inline-formula><mml:math id="M82" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and 1013 hPa are used), corresponding to 4.1 % of the area covered. Note that WHO reference concentration refers to 1 h average values, whereas we measure at each location for a few seconds. We use this comparison to show how often this threshold would be exceeded if the drive-by measurement were representative local respective situations. High <inline-formula><mml:math id="M83" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> values over motorways were mainly due to the emission of heavy duty diesel vehicles; i.e., a significant increase could be observed when we were driving behind trucks and buses. In the city center traffic congestion and the street canyon effect <xref ref-type="bibr" rid="bib1.bibx36" id="paren.23"/> can be the main cause of elevated on-road <inline-formula><mml:math id="M84" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> levels. <xref ref-type="bibr" rid="bib1.bibx52" id="text.24"/> showed in a study in Hong Kong that average pollution exposure increases by 14.5 % when stopping at a traffic light compared to fluent traffic. Other studies showed as well that the distribution of pollutants is mainly impacted by traffic flow patterns <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx36 bib1.bibx19 bib1.bibx22 bib1.bibx48" id="paren.25"/>.
The normalization using coinciding LP DOAS measurement removes the diurnal dependency but leaves the traffic flow dependency in the data, because it contributes to the city-wide air quality. The normalized on-road <inline-formula><mml:math id="M85" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>  map shown in Fig. <xref ref-type="fig" rid="Ch1.F4"/>b represents daily average values for all locations. After normalization, there exist some regions where <inline-formula><mml:math id="M86" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations are consistently higher, while in other areas the normalized concentrations are lower than the original measurements. This behavior can be explained by the time of the day when the measurements were taken: when we measured during the rush hour, the measurements were higher, while the measurements during noon are lower than the daily average. The normalization procedure increased the<?pagebreak page13247?> occurrences of WHO 1 h guideline exceedances to 14.5 % of the on-road measurements, corresponding to 17.1 % of the total area (including motorways) and 15.7 % of the area in the city center. However, the thresholds in WHO AQG are based on studies involving monitoring station data which are not measuring directly on the street. Taking the vertical and horizontal dilution factors (see Fig. <xref ref-type="fig" rid="Ch1.F5"/>, the factor 0.84 for 4 m height and 0.87 for 6 m distance) into account, we extrapolate the WHO AQG 1 h threshold value of 200 <inline-formula><mml:math id="M87" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M88" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> to the on-road level with the value of 273.7 <inline-formula><mml:math id="M89" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">145.6</mml:mn></mml:mrow></mml:math></inline-formula> ppb (200 <inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.84</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.87</mml:mn></mml:mrow></mml:math></inline-formula>)), and we then also calculated the frequency of exceedances (see Table <xref ref-type="table" rid="Ch1.T2"/>).</p>
      <p id="d1e1890">It can be seen that, especially in the downtown area (Fig. <xref ref-type="fig" rid="Ch1.F4"/>c), the values after the normalization are noticeably higher than before. This can be explained as we tried to avoid the rush hours, i.e., traffic jams, for performing the measurements. Therefore, the measured <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> level is often lower in comparison to the day average. The area with significantly lower concentrations seen in Fig. <xref ref-type="fig" rid="Ch1.F4"/> is the city park (English Garden) with no vehicle emissions and where plants could provide deposition areas for <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and particles <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx47" id="paren.26"/>.</p>
</sec>
</sec>
<?pagebreak page13248?><sec id="Ch1.S3.SS2">
  <label>3.2</label><?xmltex \opttitle{Comparison of {$\protect\chem{NO_{2}}$} concentrations at different heights and distances from the street}?><title>Comparison of <inline-formula><mml:math id="M96" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations at different heights and distances from the street</title>
      <p id="d1e1955">In order to investigate the diffusion effects of emitted <inline-formula><mml:math id="M97" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> molecules in both vertical and horizontal directions, measurements were conducted over two days (20  and 22 March 2019) using CE DOAS and CL instruments at Stachus, Munich, next to the governmental monitoring station. Since we used two different measurement techniques, the first step was to check the instrument for consistency. Side-by-side measurements next to the street (same height and distance to the street in Fig. <xref ref-type="fig" rid="Ch1.F5"/>) were used to analyze differences. We found the CL <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> to be 2 % higher, possibly due to sensitivities of the molybdenum oxide converters to <inline-formula><mml:math id="M99" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>y</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> species <xref ref-type="bibr" rid="bib1.bibx43 bib1.bibx11" id="paren.27"><named-content content-type="pre">see</named-content></xref>. We corrected the CL measurement data in order to remove those interferences.</p>
      <p id="d1e1998">Both instruments were set up next to the governmental monitoring station at Stachus, which is at a height of 4 m and has a 30 min time resolution. The CE DOAS was set up next to the street and measured at a fixed height of 1.5 m above the ground, while the CL instrument measured <inline-formula><mml:math id="M100" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at multiple heights above the ground (from 0.5  to 4 m) and at different distances from the side of the street (from 2  to 10 m). The temporal resolution for both instruments was set to 5 s. All measurements are shown in Fig. <xref ref-type="fig" rid="Ch1.F5"/>a for the different measurement heights and Fig. <xref ref-type="fig" rid="Ch1.F5"/>b for the different distances to the side of the street. Figure <xref ref-type="fig" rid="Ch1.F5"/>c shows the distribution of the ratios, and it can clearly be seen that the average concentrations decrease with height and distance. Another mobile measurement study by <xref ref-type="bibr" rid="bib1.bibx1" id="text.28"/> also demonstrates the distance-decay characteristic of the urban spatial distribution of NO, <inline-formula><mml:math id="M101" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and black carbon but on larger scales. More relevant theoretical decay research can be found in <xref ref-type="bibr" rid="bib1.bibx8 bib1.bibx9" id="text.29"/>.
Figure <xref ref-type="fig" rid="Ch1.F5"/>d shows a two-day comparison between the 30 min average <inline-formula><mml:math id="M102" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations measured with our CE DOAS at a height of 1.5 m with the CL instrument data of the governmental monitoring station at a height of 4 m. The regression plot shows a ratio of 1.23 between the measurements at 1.5  and 4 m height. In addition, the side-by-side measurement derives a factor of 0.84 with a standard deviation of 0.20, so most ratios vary from 37 % decrease with increasing height (factor <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.84</mml:mn><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.20</mml:mn><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.64</mml:mn></mml:mrow></mml:math></inline-formula>) to 5 % increase (factor <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.84</mml:mn><mml:mo>+</mml:mo><mml:mn mathvariant="normal">0.20</mml:mn><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.04</mml:mn></mml:mrow></mml:math></inline-formula>). Additional roadside measurements regarding the comparison between the 1.5  and 4 m measurement height were conducted at roadside next to the MIM building and the LfU station of Landshuter Allee on several different days during different seasons and derived a similar result. Since the inlet height for our mobile measurements is 1.5 m, we take this factor into account when comparing to monitoring station data. In addition, we analyzed how the uncertainty of the scaling factors (horizontal and vertical) contributes to the comparison with the WHO threshold shown in Table <xref ref-type="table" rid="Ch1.T2"/> and found that the percentage of exceedances can vary between 0.4 % and 23.8 %. It is because those dilution factors could vary, as they depend on factors in a small-scale environment, such as local meteorology, seasonality, local topography, urban morphology and traffic conditions. We do not assume that the scaling factors can be applied to all our mobile measurements but rather on average for our statistical analysis. For further distance-decay studies, it is essential to carry out more extensive and long-term side-by-side measurements to cover different measurement environments (such as different locations and seasons). In terms of distance to the street, measuring at the center of the street, like we did during the mobile measurements, and measuring at a distance of 6 m, which is approximately the distance of most monitoring stations to the middle of the street, the on-road measurements are 13 % higher with a standard deviation of 0.18 due to the observed diffusion effects. Those factors have to be kept in mind when comparing on-road measurements to monitoring station data or any other measurement data taken at different height levels and distances to the street. This leads to the conclusion that from the 48 % difference between the average concentrations of three monitoring stations (48 <inline-formula><mml:math id="M105" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M106" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) and the mobile measurements around the three stations (93 <inline-formula><mml:math id="M107" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M108" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), both averaged for the measurement campaign period, 27 % can be explained by the difference in inlet height and distance to the street, and the remaining 21 % is due to the fact that the monitoring stations are positioned away from pollution hot spots at crossroads according to WHO guidelines.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Summary and conclusions</title>
      <p id="d1e2133">Mobile road measurements using CE DOAS and CAPS instruments combined with an algorithm for correcting the diurnal cycle were used in order to generate a consistent pollution map of the street level <inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration in Munich. This map is not only used to identify pollution hot spots but also to figure out how representative the existing <inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> point measurements are for the whole city. Elevated <inline-formula><mml:math id="M111" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> levels can be observed mostly on motorways and busy city roads, due to the emission of heavy duty vehicles or heavy traffic volume. When averaging the mobile measurements around the monitoring stations, we derived an average <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration of 93 <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M114" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, whereas the three monitoring stations at the city center reported 48 <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M116" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> on average for the same time, so 48 % lower values. Our analysis shows that the different measurement height can account for 16 % difference (factor 0.84), and the distance of the sample inlets to the center of the street, where the mobile measurements took place, explains the 13 % (factor 0.87) lower values. Accounting for these factors still leaves about 21 % that can be attributed to pollution hot spots like busy crossroads or tunnel exits. These hot spots are not covered by monitoring stations, which is intentionally done in order to make the long-term data less dependent on local events. Nevertheless, the differences observed in the presented study show that point measurements are likely not representative for the <inline-formula><mml:math id="M117" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration in the<?pagebreak page13249?> whole city. Most network measurement sites are not capturing the concentrations people are exposed to when walking or driving at the street level but are instead focusing on long-term trends. Our study illustrates the importance of combining different measurement techniques to capture spatial and temporal patterns within a city and derive concentration values that are representative for the air most people breathe in.</p>
      <p id="d1e2232">The pollution maps generated in this project provide valuable information for future urban planning and the design of control measures of environment pollution. Furthermore, it can provide guidelines for identifying representative locations for air pollution monitoring stations in a city. Additionally, the observed spatial distribution of <inline-formula><mml:math id="M118" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations is also beneficial to the validation of chemical transport models and assessment studies of the impact of air pollution on human health.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e2251">The data that support the findings of this study are available on request from the corresponding author Ying Zhu and Mark Wenig. The data are not publicly available due to them containing information that could compromise research participant consent.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e2254">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/acp-20-13241-2020-supplement" xlink:title="pdf">https://doi.org/10.5194/acp-20-13241-2020-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e2263">YZ, MW and JC designed the experiments. YZ, GK and XB carried them out. KLC simulated the results from the GEOS-Chem model. YZ prepared the manuscript with contributions from all coauthors.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e2269">The authors declare that they have no conflict of interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e2275">The work described in this paper was jointly supported by the major research instrumentation program INST 86/1499 FUGG.
In addition, Ying Zhu, Jia Chen, Xiao Bi, and  Florian Dietrich  was partly funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) – CH 1792/2-1 and supported by Technical University of Munich – Institute for Advanced Study, funded by the German Excellence Initiative and the European Union Seventh Framework Program under grant agreement number 291763.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e2280">This work was supported by the German Research Foundation (DFG) and the Technical University of<?xmltex \hack{\newline}?> Munich (TUM) in the framework of the Open Access<?xmltex \hack{\newline}?> Publishing Program.</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e2290">This paper was edited by Ronald Cohen and reviewed by three anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Apte et al.(2017)</label><?label apte2017high?><mixed-citation>
Apte, J. S., Messier, K. P., Gani, S., Brauer, M., Kirchstetter, T. W., Lunden,
M. M., Marshall, J. D., Portier, C. J., Vermeulen, R. C., and Hamburg, S. P.:
High-resolution air pollution mapping with Google street view cars:
exploiting big data, Environ. Sci. Technol., 51, 6999–7008,
2017.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Ball and Jones(2003)</label><?label ball2003broad?><mixed-citation>
Ball, S. M. and Jones, R. L.: Broad-band cavity ring-down spectroscopy,
Chem. Rev., 103, 5239–5262, 2003.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Ban-Weiss et al.(2008)</label><?label ban2008long?><mixed-citation>
Ban-Weiss, G. A., McLaughlin, J. P., Harley, R. A., Lunden, M. M.,
Kirchstetter, T. W., Kean, A. J., Strawa, A. W., Stevenson, E. D., and
Kendall, G. R.: Long-term changes in emissions of nitrogen oxides and
particulate matter from on-road gasoline and diesel vehicles, Atmos.
Environ., 42, 220–232, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Berden et al.(2000)</label><?label berden2000cavity?><mixed-citation>
Berden, G., Peeters, R., and Meijer, G.: Cavity ring-down spectroscopy:
Experimental schemes and applications, Int. Rev. Phys.
Chem., 19, 565–607, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Brown et al.(2002)</label><?label brown2002cavity?><mixed-citation>Brown, S., Stark, H., and Ravishankara, A.: Cavity ring-down spectroscopy for
atmospheric trace gas detection: application to the nitrate radical (NO<inline-formula><mml:math id="M119" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>),
Appl. Phys. B, 75, 173–182, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Chan et al.(2017)</label><?label chan2017a?><mixed-citation>Chan, K. L., Wang, S., Liu, C., Zhou, B., Wenig, M. O., and Saiz-Lopez, A.: On
the summertime air quality and related photochemical processes in the
megacity Shanghai, China, Sci. Total Environ., 580,
974–983, <ext-link xlink:href="https://doi.org/10.1016/j.scitotenv.2016.12.052" ext-link-type="DOI">10.1016/j.scitotenv.2016.12.052</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Chaparro-Suarez et al.(2011)</label><?label CHAPARROSUAREZ20115742?><mixed-citation>Chaparro-Suarez, I., Meixner, F., and Kesselmeier, J.: Nitrogen dioxide (NO<inline-formula><mml:math id="M120" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>)
uptake by vegetation controlled by atmospheric concentrations and plant
stomatal aperture, Atmos. Environ., 45, 5742–5750,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2011.07.021" ext-link-type="DOI">10.1016/j.atmosenv.2011.07.021</ext-link>,
2011.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Choi et al.(2012)</label><?label choi2012prevalence?><mixed-citation>
Choi, W., He, M., Barbesant, V., Kozawa, K. H., Mara, S., Winer, A. M., and
Paulson, S. E.: Prevalence of wide area impacts downwind of freeways under
pre-sunrise stable atmospheric conditions, Atmos. Environ., 62,
318–327, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Choi et al.(2014)</label><?label choi2014factors?><mixed-citation>Choi, W., Winer, A. M., and Paulson, S. E.: Factors controlling pollutant plume length downwind of major roadways in nocturnal surface inversions, Atmos. Chem. Phys., 14, 6925–6940, <ext-link xlink:href="https://doi.org/10.5194/acp-14-6925-2014" ext-link-type="DOI">10.5194/acp-14-6925-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Commission(2008)</label><?label union2008directive?><mixed-citation>
Commission, E.: Directive 2008/50/EC of the European Parliament and of the
Council of 21 May 2008 on ambient air quality and cleaner air for Europe,
Official Journal of the European Union, 19 pp., 2008.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Dunlea et al.(2007)</label><?label Dunlea2007?><mixed-citation>Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., San Martini,
F., Sheehy, P. M., Zahniser, M. S., Shorter, J. H., Wormhoudt, J. C., Lamb,
B. K., Allwine, E. J., Gaffney, J. S., Marley, N. A., Grutter, M., Marquez,
C., Blanco, S., Cardenas, B., Retama, A., Ramos Villegas, C. R., Kolb,
C. E., Molina, L. T., and Molina, M. J.: Evaluation of nitrogen dioxide
chemiluminescence monitors in a polluted urban environment, Atmos.
Chem. Phys., 7, 2691–2704, <ext-link xlink:href="https://doi.org/10.5194/acp-7-2691-2007" ext-link-type="DOI">10.5194/acp-7-2691-2007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>EEA(2017)</label><?label 2017Europe?><mixed-citation>
EEA: Air quality in Europe–2017 Report, Tech. Rep., European Environment
Agency Copenhagen, Denmark, 41–42, 2017.</mixed-citation></ref>
      <?pagebreak page13250?><ref id="bib1.bibx13"><label>Engeln et al.(1996)</label><?label Engeln1996?><mixed-citation>Engeln, R., von Helden, G., Berden, G., and Meijer, G.: Phase shift cavity ring
down absorption spectroscopy, Chem. Phys. Lett., 262, 105–109,
<ext-link xlink:href="https://doi.org/10.1016/0009-2614(96)01048-2" ext-link-type="DOI">10.1016/0009-2614(96)01048-2</ext-link>,
1996.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Fu et al.(2017)</label><?label Fu2017?><mixed-citation>Fu, X., Liu, J., Ban-Weiss, G. A., Zhang, J., Huang, X., Ouyang, B., Popoola,
O., and Tao, S.: Effects of canyon geometry on the distribution of
traffic-related air pollution in a large urban area: Implications of a
multi-canyon air pollution dispersion model, Atmos. Environ., 165,
111–121, <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2017.06.031" ext-link-type="DOI">10.1016/j.atmosenv.2017.06.031</ext-link>,
2017.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Ge et al.(2013)</label><?label ge2013nitrogen?><mixed-citation>
Ge, B., Sun, Y., Liu, Y., Dong, H., Ji, D., Jiang, Q., Li, J., and Wang, Z.:
Nitrogen dioxide measurement by cavity attenuated phase shift spectroscopy
(CAPS) and implications in ozone production efficiency and nitrate formation
in Beijing, China, J. Geophys. Res.-Atmos., 118,
9499–9509, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Henderson et al.(2007)</label><?label henderson2007application?><mixed-citation>
Henderson, S. B., Beckerman, B., Jerrett, M., and Brauer, M.: Application of
land use regression to estimate long-term concentrations of traffic-related
nitrogen oxides and fine particulate matter, Environ. Sci.
Technol., 41, 2422–2428, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Herbelin et al.(1980)</label><?label Herbelin1980?><mixed-citation>Herbelin, J. M., McKay, J. A., Kwok, M. A., Ueunten, R. H., Urevig, D. S.,
Spencer, D. J., and Benard, D. J.: Sensitive measurement of photon lifetime
and true reflectances in an optical cavity by a phase-shift method, Appl.
Opt., 19, 144–147, <ext-link xlink:href="https://doi.org/10.1364/AO.19.000144" ext-link-type="DOI">10.1364/AO.19.000144</ext-link>, 1980.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Hermans et al.(1999)</label><?label Hermans1999?><mixed-citation>Hermans, C., Vandaele, A. C., Carleer, M., Fally, S., Colin, R., Jenouvrier,
A., Coquart, B., and Mérienne, M.-F.: Absorption cross-sections of
atmospheric constituents: NO<inline-formula><mml:math id="M121" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, O<inline-formula><mml:math id="M122" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and H<inline-formula><mml:math id="M123" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O, Environ. Sci.
Pollut. Res., 6, 151–158, <ext-link xlink:href="https://doi.org/10.1007/BF02987620" ext-link-type="DOI">10.1007/BF02987620</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>Huan and Kebin(2012)</label><?label Huan2012?><mixed-citation>Huan, L. and Kebin, H.: Traffic Optimization: A New Way for Air Pollution
Control in China's Urban Areas, Environ. Sci. Technol., 46,
5660–5661, <ext-link xlink:href="https://doi.org/10.1021/es301778b" ext-link-type="DOI">10.1021/es301778b</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Huang et al.(2014)</label><?label Huang2014?><mixed-citation>
Huang, R.-J., Zhang, Y., Bozzetti, C., Ho, K.-F., Cao, J.-J., Han, Y.,
Daellenbach, K. R., Slowik, J. G., Platt, S. M., Canonaco, F., Zotter, P.,
Wolf, R., Pieber, S. M.,
Bruns, E. A.,
Crippa, M.,
Ciarelli, G.,
Piazzalunga, A.,
Schwikowski, M.,
Abbaszade, G.,
Schnelle-Kreis, J.,
Zimmermann, R.,
An, Z.,
Szidat, S.,
Baltensperger, U.,
Haddad, I. E.,
and Prévôt, A. S. H.: High
secondary aerosol contribution to particulate pollution during haze events in
China, Nature, 514, 218–222, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Jang and Kamens(2001)</label><?label Jang2001?><mixed-citation>Jang, M. and Kamens, R. M.: Characterization of Secondary Aerosol from the
Photooxidation of Toluene in the Presence of NO<inline-formula><mml:math id="M124" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> and 1-Propene,
Environ. Sci. Technol., 35, 3626–3639, <ext-link xlink:href="https://doi.org/10.1021/es010676+" ext-link-type="DOI">10.1021/es010676+</ext-link>,
2001.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Kaur et al.(2007)</label><?label Kaur2007?><mixed-citation>Kaur, S., Nieuwenhuijsen, M., and Colvile, R.: Fine particulate matter and
carbon monoxide exposure concentrations in urban street transport
microenvironments, Atmos. Environ., 41, 4781–4810,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2007.02.002" ext-link-type="DOI">10.1016/j.atmosenv.2007.02.002</ext-link>,
2007.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Kebabian et al.(2005a)</label><?label Kebabian2005?><mixed-citation>Kebabian, P. L., Herndon, S. C., and Freedman, A.: Detection of Nitrogen
Dioxide by Cavity Attenuated Phase Shift Spectroscopy, Anal. Chem.,
77, 724–728, <ext-link xlink:href="https://doi.org/10.1021/ac048715y" ext-link-type="DOI">10.1021/ac048715y</ext-link>,
2005a.</mixed-citation></ref>
      <ref id="bib1.bibx24"><label>Kebabian et al.(2005b)</label><?label kebabian2005detection?><mixed-citation>
Kebabian, P. L., Herndon, S. C., and Freedman, A.: Detection of nitrogen
dioxide by cavity attenuated phase shift spectroscopy, Anal. Chem.,
77, 724–728, 2005b.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Kebabian et al.(2008)</label><?label kebabian2008practical?><mixed-citation>
Kebabian, P. L., Wood, E. C., Herndon, S. C., and Freedman, A.: A practical
alternative to chemiluminescence-based detection of nitrogen dioxide: Cavity
attenuated phase shift spectroscopy, Environ. Sci. Technol., 42,
6040–6045, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Kirchstetter et al.(1999)</label><?label kirchstetter1999road?><mixed-citation>
Kirchstetter, T. W., Harley, R. A., Kreisberg, N. M., Stolzenburg, M. R., and
Hering, S. V.: On-road measurement of fine particle and nitrogen oxide
emissions from light-and heavy-duty motor vehicles, Atmos. Environ.,
33, 2955–2968, 1999.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Kraus(2005)</label><?label kraus2005?><mixed-citation>
Kraus, S.: DOASIS A Framework Design for DOAS, Ph.D. thesis, Combined
Faculties for Mathematics and for Computer Science, University of Mannheim,
2005.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Kundu et al.(2019)</label><?label Kundu2018?><mixed-citation>Kundu, S., Deming, B. L., Lew, M. M., Bottorff, B. P., Rickly, P., Stevens, P. S., Dusanter, S., Sklaveniti, S., Leonardis, T., Locoge, N., and Wood, E. C.: Peroxy radical measurements by ethane – nitric oxide chemical amplification and laser-induced fluorescence during the IRRONIC field campaign in a forest in Indiana, Atmos. Chem. Phys., 19, 9563–9579, <ext-link xlink:href="https://doi.org/10.5194/acp-19-9563-2019" ext-link-type="DOI">10.5194/acp-19-9563-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Langridge et al.(2006)</label><?label Langridge2006?><mixed-citation>Langridge, J. M., Ball, S. M., and Jones, R. L.: A compact broadband cavity
enhanced absorption spectrometer for detection of atmospheric NO<inline-formula><mml:math id="M125" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> using
light emitting diodes, Analyst, 131, 916–922, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx30"><label>LfU(2015)</label><?label Lfu2015?><mixed-citation>
LfU: Untersuchung der räumlichen Verteilung der NOx-Belastung im Umfeld von
vorhandenen, hochbelasteten Luftmessstationen, Abschlussbericht, Tech. Rep.,
Bayerisches Landesamt für Umwelt, 16–23, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx31"><label>LfU(2019)</label><?label 2019LfuWebpage?><mixed-citation>LfU, B.: Aktuelle Werte der bayerischen Luftmessstationen, available at:
<uri>https://www.lfu.bayern.de/luft/immissionsmessungen/messwerte/index.htm</uri>,
last access: 29 November 2019.</mixed-citation></ref>
      <ref id="bib1.bibx32"><label>Massman(1998)</label><?label massman1998review?><mixed-citation>Massman, W.: A review of the molecular diffusivities of H<inline-formula><mml:math id="M126" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O, CO<inline-formula><mml:math id="M127" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, CH<inline-formula><mml:math id="M128" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula>, CO, O<inline-formula><mml:math id="M129" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>,
SO<inline-formula><mml:math id="M130" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, NH<inline-formula><mml:math id="M131" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, N<inline-formula><mml:math id="M132" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O, NO, and NO<inline-formula><mml:math id="M133" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in air, O<inline-formula><mml:math id="M134" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and N<inline-formula><mml:math id="M135" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> near STP, Atmos.
Environ., 32, 1111–1127, 1998.</mixed-citation></ref>
      <ref id="bib1.bibx33"><label>Min et al.(2016)</label><?label Min2016?><mixed-citation>Min, K.-E., Washenfelder, R. A., Dubé, W. P., Langford, A. O., Edwards,
P. M., Zarzana, K. J., Stutz, J., Lu, K., Rohrer, F., Zhang, Y., and Brown,
S. S.: A broadband cavity enhanced absorption spectrometer for aircraft
measurements of glyoxal, methylglyoxal, nitrous acid, nitrogen dioxide, and
water vapor, Atmos. Meas. Tech., 9, 423–440,
<ext-link xlink:href="https://doi.org/10.5194/amt-9-423-2016" ext-link-type="DOI">10.5194/amt-9-423-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx34"><label>Ning et al.(2012)</label><?label Ning2012?><mixed-citation>Ning, Z., Wubulihairen, M., and Yang, F.: PM, NO<inline-formula><mml:math id="M136" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> and butane emissions
from on-road vehicle fleets in Hong Kong and their implications on
emission control policy, Atmos. Environ., 61, 265–274,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2012.07.047" ext-link-type="DOI">10.1016/j.atmosenv.2012.07.047</ext-link>,
2012.</mixed-citation></ref>
      <ref id="bib1.bibx35"><label>Platt et al.(2009)</label><?label Platt2009?><mixed-citation>Platt, U., Meinen, J., Pöhler, D., and Leisner, T.: Broadband Cavity
Enhanced Differential Optical Absorption Spectroscopy (CE-DOAS) –
applicability and corrections, Atmos. Meas. Tech., 2,
713–723, <ext-link xlink:href="https://doi.org/10.5194/amt-2-713-2009" ext-link-type="DOI">10.5194/amt-2-713-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx36"><label>Rakowska et al.(2014)</label><?label Rakowska2014?><mixed-citation>Rakowska, A., Wong, K. C., Townsend, T., Chan, K. L., Westerdahl, D., Ng, S.,
Močnik, G., Drinovec, L., and Ning, Z.: Impact of traffic volume and
composition on the air quality and pedestrian exposure in urban street
canyon, Atmos. Environ., 98, 260–270,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2014.08.073" ext-link-type="DOI">10.1016/j.atmosenv.2014.08.073</ext-link>,
2014.</mixed-citation></ref>
      <ref id="bib1.bibx37"><label>Rothman et al.(2003)</label><?label Rothman2003?><mixed-citation>Rothman, L., Barbe, A., Benner, D. C., Brown, L., Camy-Peyret, C., Carleer, M.,
Chance, K., Clerbaux, C., Dana, V., Devi, V., Fayt, A., Flaud, J.-M.,
Gamache, R., Goldman, A., Jacquemart, D., Jucks, K., Lafferty, W., Mandin,
J.-Y., Massie, S., Nemtchinov, V., Newnham, D., Perrin, A., Rinsland, C.,
Schroeder, J., Smith, K., Smith, M., Tang, K., Toth, R., Auwera, J. V.,
Varanasi, P., and Yoshino, K.: The HITRAN molecular spectroscopic database:
edition of 2000 including updates through 2001, J. Quant.
Spectrosc. Ra., 82, 5–44,
<ext-link xlink:href="https://doi.org/10.1016/S0022-4073(03)00146-8" ext-link-type="DOI">10.1016/S0022-4073(03)00146-8</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bibx38"><label>Thalman and Volkamer(2010)</label><?label Thalman2010?><mixed-citation>Thalman, R. and Volkamer, R.: Inherent calibration of a blue LED-CE-DOAS
instrument to measure iodine oxide, glyoxal, methyl glyoxal, nitrogen
dioxide, water vapour <?pagebreak page13251?>and aerosol extinction in open cavity mode, Atmos.
Meas. Tech., 3, 1797–1814, <ext-link xlink:href="https://doi.org/10.5194/amt-3-1797-2010" ext-link-type="DOI">10.5194/amt-3-1797-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx39"><label>UBA(2017)</label><?label UBA2017?><mixed-citation>
UBA: Air quality 2016 (Preliminary Evaluation), Tech. rep., Umweltbundesamt
(German Environment Agency),   2017.</mixed-citation></ref>
      <ref id="bib1.bibx40"><label>Uhrner et al.(2007)</label><?label Uhrner2007?><mixed-citation>Uhrner, U., von Löwis, S., Vehkamäki, H., Wehner, B., Bräsel, S.,
Hermann, M., Stratmann, F., Kulmala, M., and Wiedensohler, A.: Dilution and
aerosol dynamics within a diesel car exhaust plume-CFD simulations of
on-road measurement conditions, Atmos. Environ., 41, 7440–7461,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2007.05.057" ext-link-type="DOI">10.1016/j.atmosenv.2007.05.057</ext-link>,
2007.</mixed-citation></ref>
      <ref id="bib1.bibx41"><label>Vandaele et al.(2002)</label><?label Vandaele2002?><mixed-citation>Vandaele, A. C., Hermans, C., Fally, S., Carleer, M., Colin, R., Mérienne,
M.-F., Jenouvrier, A., and Coquart, B.: High-resolution Fourier transform
measurement of the NO<inline-formula><mml:math id="M137" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> visible and near-infrared absorption cross
sections: Temperature and pressure effects, J. Geophys. Res.-Atmos., 107, 4348, <ext-link xlink:href="https://doi.org/10.1029/2001JD000971" ext-link-type="DOI">10.1029/2001JD000971</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx42"><label>Venables et al.(2006)</label><?label Venables2006?><mixed-citation>Venables, D. S., Gherman, T., Orphal, J., Wenger, J. C., and Ruth, A. A.: High
sensitivity in situ monitoring of NO<inline-formula><mml:math id="M138" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> in an atmospheric simulation
chamber using incoherent broadband cavity-enhanced absorption spectroscopy,
Environ. Sci. Technol., 40, 6758–6763, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx43"><label>Villena et al.(2012)</label><?label Villena2012?><mixed-citation>Villena, G., Bejan, I., Kurtenbach, R., Wiesen, P., and Kleffmann, J.:
Interferences of commercial NO<inline-formula><mml:math id="M139" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> instruments in the urban atmosphere and
in a smog chamber, Atmos. Meas. Tech., 5, 149–159,
<ext-link xlink:href="https://doi.org/10.5194/amt-5-149-2012" ext-link-type="DOI">10.5194/amt-5-149-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx44"><label>Vogt et al.(2003)</label><?label Vogt2003?><mixed-citation>Vogt, R., Scheer, V., Casati, R., and Benter, T.: On-Road Measurement of
Particle Emission in the Exhaust Plume of a Diesel Passenger Car,
Environ. Sci. Technol., 37, 4070–4076, <ext-link xlink:href="https://doi.org/10.1021/es0300315" ext-link-type="DOI">10.1021/es0300315</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bibx45"><label>Volkamer et al.(2005)</label><?label Volkamer2005?><mixed-citation>Volkamer, R., Spietz, P., Burrows, J., and Platt, U.: High-resolution
absorption cross-section of glyoxal in the UV–VIS and IR spectral ranges,
J. Photoch. Photobio. A, 172, 35–46,
<ext-link xlink:href="https://doi.org/10.1016/j.jphotochem.2004.11.011" ext-link-type="DOI">10.1016/j.jphotochem.2004.11.011</ext-link>,
2005.</mixed-citation></ref>
      <ref id="bib1.bibx46"><label>Washenfelder et al.(2008)</label><?label Washenfelder2008?><mixed-citation>Washenfelder, R. A., Langford, A. O., Fuchs, H., and Brown, S. S.: Measurement
of glyoxal using an incoherent broadband cavity enhanced absorption
spectrometer, Atmos. Chem. Phys., 8, 7779–7793,
<ext-link xlink:href="https://doi.org/10.5194/acp-8-7779-2008" ext-link-type="DOI">10.5194/acp-8-7779-2008</ext-link>, 2008.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx47"><label>Wesely and Hicks(2000)</label><?label wesely2000review?><mixed-citation>
Wesely, M. and Hicks, B.: A review of the current status of knowledge on dry
deposition, Atmos. Environ., 34, 2261–2282, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx48"><label>Westerdahl et al.(2005)</label><?label Westerdahl2005?><mixed-citation>Westerdahl, D., Fruin, S., Sax, T., Fine, P. M., and Sioutas, C.: Mobile
platform measurements of ultrafine particles and associated pollutant
concentrations on freeways and residential streets in Los Angeles,
Atmos. Environ., 39, 3597–3610,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2005.02.034" ext-link-type="DOI">10.1016/j.atmosenv.2005.02.034</ext-link>,
2005.</mixed-citation></ref>
      <ref id="bib1.bibx49"><label>Xie et al.(2019)</label><?label Xie2019?><mixed-citation>Xie, C., Xu, W., Wang, J., Wang, Q., Liu, D., Tang, G., Chen, P., Du, W., Zhao,
J., Zhang, Y., Zhou, W., Han, T., Bian, Q., Li, J., Fu, P., Wang, Z., Ge, X.,
Allan, J., Coe, H., and Sun, Y.: Vertical characterization of aerosol optical
properties and brown carbon in winter in urban Beijing, China, Atmos.
Chem. Phys., 19, 165–179, <ext-link xlink:href="https://doi.org/10.5194/acp-19-165-2019" ext-link-type="DOI">10.5194/acp-19-165-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx50"><label>Xie et al.(2015)</label><?label xie2015?><mixed-citation>Xie, Y., Zhao, B., Zhang, L., and Luo, R.: Spatiotemporal variations of PM<inline-formula><mml:math id="M140" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>
and PM<inline-formula><mml:math id="M141" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula> concentrations between 31 Chinese cities and their relationships
with SO<inline-formula><mml:math id="M142" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, NO<inline-formula><mml:math id="M143" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, CO and O<inline-formula><mml:math id="M144" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, Particuology, 20, 141–149, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx51"><label>Yoo et al.(2014)</label><?label yoo2014new?><mixed-citation>Yoo, J.-M., Lee, Y.-R., Kim, D., Jeong, M.-J., Stockwell, W. R., Kundu, P. K.,
Oh, S.-M., Shin, D.-B., and Lee, S.-J.: New indices for wet scavenging of air
pollutants (O<inline-formula><mml:math id="M145" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, CO, NO<inline-formula><mml:math id="M146" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, SO<inline-formula><mml:math id="M147" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and PM<inline-formula><mml:math id="M148" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula>) by summertime rain, Atmos.
Environ., 82, 226–237, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx52"><label>Zhu et al.(2018)</label><?label Zhu2018?><mixed-citation>Zhu, Y., Chan, K. L., Lam, Y. F., Horbanski, M., Pöhler, D., Boll, J.,
Lipkowitsch, I., Ye, S., and Wenig, M.: Analysis of spatial and temporal
patterns of on-road <inline-formula><mml:math id="M149" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations in Hong Kong, Atmos.
Meas. Tech., 11, 6719–6734, <ext-link xlink:href="https://doi.org/10.5194/amt-11-6719-2018" ext-link-type="DOI">10.5194/amt-11-6719-2018</ext-link>, 2018.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Spatial and temporal representativeness of point measurements for nitrogen dioxide pollution levels in cities</article-title-html>
<abstract-html><p>In many cities around the world the overall air quality is improving, but at the same time nitrogen dioxide (NO<sub>2</sub>) trends show stagnating values and in many cases could not be reduced below air quality standards recommended by the World Health Organization (WHO). Many large cities have built monitoring stations to continuously measure different air pollutants. While most stations follow defined rules in terms of measurement height and distance to traffic emissions, the question remains of how representative are those point measurements for the city-wide air quality. The question of the spatial coverage of a point measurement is important because it defines the area of influence and coverage of monitoring networks, determines how to assimilate monitoring data into model simulations or compare to satellite data with a coarser resolution, and is essential to assess the impact of the acquired data on public health.</p><p>In order to answer this question, we combined different measurement data sets consisting of path-averaging remote sensing data and in situ point measurements in stationary and mobile setups from a measurement campaign that took place in Munich, Germany, in June and July 2016. We developed an algorithm to strip temporal from spatial patterns in order to construct a consistent NO<sub>2</sub> pollution map for Munich. Continuous long-path differential optical absorption spectroscopy (LP DOAS) measurements were complemented with mobile cavity-enhanced (CE) DOAS, chemiluminescence (CL) and cavity attenuated phase shift (CAPS) instruments and were compared to monitoring stations and satellite data. In order to generate a consistent composite map, the LP DOAS diurnal cycle has been used to normalize for the time of the day dependency of the source patterns, so that spatial and temporal patterns can be analyzed separately. The resulting concentration map visualizes pollution hot spots at traffic junctions and tunnel exits in Munich, providing insights into the strong spatial variations. On the other hand, this database is beneficial to the urban planning and the design of control measures of environment pollution. Directly comparing on-street mobile measurements in the vicinity of monitoring stations resulted in a difference of 48&thinsp;%. For the extrapolation of the monitoring station data to street level, we determined the influence of the measuring height and distance to the street. We found that a measuring height of 4&thinsp;m, at which the Munich monitoring stations measure, results in 16&thinsp;% lower average concentrations than a measuring height of 1.5&thinsp;m, which is the height of the inlet of our mobile measurements and a typical pedestrian breathing height. The horizontal distance of most stations to the center of the street of about 6&thinsp;m also results in an average reduction of 13&thinsp;% compared to street level concentration. A difference of 21&thinsp;% in the NO<sub>2</sub> concentrations remained, which could be an indication that city-wide measurements are needed for capturing the full range and variability of concentrations for assessing pollutant exposure and air quality in cities.</p></abstract-html>
<ref-html id="bib1.bib1"><label>Apte et al.(2017)</label><mixed-citation>
Apte, J. S., Messier, K. P., Gani, S., Brauer, M., Kirchstetter, T. W., Lunden,
M. M., Marshall, J. D., Portier, C. J., Vermeulen, R. C., and Hamburg, S. P.:
High-resolution air pollution mapping with Google street view cars:
exploiting big data, Environ. Sci. Technol., 51, 6999–7008,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Ball and Jones(2003)</label><mixed-citation>
Ball, S. M. and Jones, R. L.: Broad-band cavity ring-down spectroscopy,
Chem. Rev., 103, 5239–5262, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Ban-Weiss et al.(2008)</label><mixed-citation>
Ban-Weiss, G. A., McLaughlin, J. P., Harley, R. A., Lunden, M. M.,
Kirchstetter, T. W., Kean, A. J., Strawa, A. W., Stevenson, E. D., and
Kendall, G. R.: Long-term changes in emissions of nitrogen oxides and
particulate matter from on-road gasoline and diesel vehicles, Atmos.
Environ., 42, 220–232, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Berden et al.(2000)</label><mixed-citation>
Berden, G., Peeters, R., and Meijer, G.: Cavity ring-down spectroscopy:
Experimental schemes and applications, Int. Rev. Phys.
Chem., 19, 565–607, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Brown et al.(2002)</label><mixed-citation>
Brown, S., Stark, H., and Ravishankara, A.: Cavity ring-down spectroscopy for
atmospheric trace gas detection: application to the nitrate radical (NO<sub>3</sub>),
Appl. Phys. B, 75, 173–182, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Chan et al.(2017)</label><mixed-citation>
Chan, K. L., Wang, S., Liu, C., Zhou, B., Wenig, M. O., and Saiz-Lopez, A.: On
the summertime air quality and related photochemical processes in the
megacity Shanghai, China, Sci. Total Environ., 580,
974–983, <a href="https://doi.org/10.1016/j.scitotenv.2016.12.052" target="_blank">https://doi.org/10.1016/j.scitotenv.2016.12.052</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Chaparro-Suarez et al.(2011)</label><mixed-citation>
Chaparro-Suarez, I., Meixner, F., and Kesselmeier, J.: Nitrogen dioxide (NO<sub>2</sub>)
uptake by vegetation controlled by atmospheric concentrations and plant
stomatal aperture, Atmos. Environ., 45, 5742–5750,
<a href="https://doi.org/10.1016/j.atmosenv.2011.07.021" target="_blank">https://doi.org/10.1016/j.atmosenv.2011.07.021</a>,
2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Choi et al.(2012)</label><mixed-citation>
Choi, W., He, M., Barbesant, V., Kozawa, K. H., Mara, S., Winer, A. M., and
Paulson, S. E.: Prevalence of wide area impacts downwind of freeways under
pre-sunrise stable atmospheric conditions, Atmos. Environ., 62,
318–327, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Choi et al.(2014)</label><mixed-citation>
Choi, W., Winer, A. M., and Paulson, S. E.: Factors controlling pollutant plume length downwind of major roadways in nocturnal surface inversions, Atmos. Chem. Phys., 14, 6925–6940, <a href="https://doi.org/10.5194/acp-14-6925-2014" target="_blank">https://doi.org/10.5194/acp-14-6925-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Commission(2008)</label><mixed-citation>
Commission, E.: Directive 2008/50/EC of the European Parliament and of the
Council of 21 May 2008 on ambient air quality and cleaner air for Europe,
Official Journal of the European Union, 19 pp., 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Dunlea et al.(2007)</label><mixed-citation>
Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., San Martini,
F., Sheehy, P. M., Zahniser, M. S., Shorter, J. H., Wormhoudt, J. C., Lamb,
B. K., Allwine, E. J., Gaffney, J. S., Marley, N. A., Grutter, M., Marquez,
C., Blanco, S., Cardenas, B., Retama, A., Ramos Villegas, C. R., Kolb,
C. E., Molina, L. T., and Molina, M. J.: Evaluation of nitrogen dioxide
chemiluminescence monitors in a polluted urban environment, Atmos.
Chem. Phys., 7, 2691–2704, <a href="https://doi.org/10.5194/acp-7-2691-2007" target="_blank">https://doi.org/10.5194/acp-7-2691-2007</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>EEA(2017)</label><mixed-citation>
EEA: Air quality in Europe–2017 Report, Tech. Rep., European Environment
Agency Copenhagen, Denmark, 41–42, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Engeln et al.(1996)</label><mixed-citation>
Engeln, R., von Helden, G., Berden, G., and Meijer, G.: Phase shift cavity ring
down absorption spectroscopy, Chem. Phys. Lett., 262, 105–109,
<a href="https://doi.org/10.1016/0009-2614(96)01048-2" target="_blank">https://doi.org/10.1016/0009-2614(96)01048-2</a>,
1996.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Fu et al.(2017)</label><mixed-citation>
Fu, X., Liu, J., Ban-Weiss, G. A., Zhang, J., Huang, X., Ouyang, B., Popoola,
O., and Tao, S.: Effects of canyon geometry on the distribution of
traffic-related air pollution in a large urban area: Implications of a
multi-canyon air pollution dispersion model, Atmos. Environ., 165,
111–121, <a href="https://doi.org/10.1016/j.atmosenv.2017.06.031" target="_blank">https://doi.org/10.1016/j.atmosenv.2017.06.031</a>,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Ge et al.(2013)</label><mixed-citation>
Ge, B., Sun, Y., Liu, Y., Dong, H., Ji, D., Jiang, Q., Li, J., and Wang, Z.:
Nitrogen dioxide measurement by cavity attenuated phase shift spectroscopy
(CAPS) and implications in ozone production efficiency and nitrate formation
in Beijing, China, J. Geophys. Res.-Atmos., 118,
9499–9509, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Henderson et al.(2007)</label><mixed-citation>
Henderson, S. B., Beckerman, B., Jerrett, M., and Brauer, M.: Application of
land use regression to estimate long-term concentrations of traffic-related
nitrogen oxides and fine particulate matter, Environ. Sci.
Technol., 41, 2422–2428, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Herbelin et al.(1980)</label><mixed-citation>
Herbelin, J. M., McKay, J. A., Kwok, M. A., Ueunten, R. H., Urevig, D. S.,
Spencer, D. J., and Benard, D. J.: Sensitive measurement of photon lifetime
and true reflectances in an optical cavity by a phase-shift method, Appl.
Opt., 19, 144–147, <a href="https://doi.org/10.1364/AO.19.000144" target="_blank">https://doi.org/10.1364/AO.19.000144</a>, 1980.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Hermans et al.(1999)</label><mixed-citation>
Hermans, C., Vandaele, A. C., Carleer, M., Fally, S., Colin, R., Jenouvrier,
A., Coquart, B., and Mérienne, M.-F.: Absorption cross-sections of
atmospheric constituents: NO<sub>2</sub>, O<sub>2</sub>, and H<sub>2</sub>O, Environ. Sci.
Pollut. Res., 6, 151–158, <a href="https://doi.org/10.1007/BF02987620" target="_blank">https://doi.org/10.1007/BF02987620</a>, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Huan and Kebin(2012)</label><mixed-citation>
Huan, L. and Kebin, H.: Traffic Optimization: A New Way for Air Pollution
Control in China's Urban Areas, Environ. Sci. Technol., 46,
5660–5661, <a href="https://doi.org/10.1021/es301778b" target="_blank">https://doi.org/10.1021/es301778b</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Huang et al.(2014)</label><mixed-citation>
Huang, R.-J., Zhang, Y., Bozzetti, C., Ho, K.-F., Cao, J.-J., Han, Y.,
Daellenbach, K. R., Slowik, J. G., Platt, S. M., Canonaco, F., Zotter, P.,
Wolf, R., Pieber, S. M.,
Bruns, E. A.,
Crippa, M.,
Ciarelli, G.,
Piazzalunga, A.,
Schwikowski, M.,
Abbaszade, G.,
Schnelle-Kreis, J.,
Zimmermann, R.,
An, Z.,
Szidat, S.,
Baltensperger, U.,
Haddad, I. E.,
and Prévôt, A. S. H.: High
secondary aerosol contribution to particulate pollution during haze events in
China, Nature, 514, 218–222, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Jang and Kamens(2001)</label><mixed-citation>
Jang, M. and Kamens, R. M.: Characterization of Secondary Aerosol from the
Photooxidation of Toluene in the Presence of NO<sub><i>x</i></sub> and 1-Propene,
Environ. Sci. Technol., 35, 3626–3639, <a href="https://doi.org/10.1021/es010676+" target="_blank">https://doi.org/10.1021/es010676+</a>,
2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Kaur et al.(2007)</label><mixed-citation>
Kaur, S., Nieuwenhuijsen, M., and Colvile, R.: Fine particulate matter and
carbon monoxide exposure concentrations in urban street transport
microenvironments, Atmos. Environ., 41, 4781–4810,
<a href="https://doi.org/10.1016/j.atmosenv.2007.02.002" target="_blank">https://doi.org/10.1016/j.atmosenv.2007.02.002</a>,
2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Kebabian et al.(2005a)</label><mixed-citation>
Kebabian, P. L., Herndon, S. C., and Freedman, A.: Detection of Nitrogen
Dioxide by Cavity Attenuated Phase Shift Spectroscopy, Anal. Chem.,
77, 724–728, <a href="https://doi.org/10.1021/ac048715y" target="_blank">https://doi.org/10.1021/ac048715y</a>,
2005a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Kebabian et al.(2005b)</label><mixed-citation>
Kebabian, P. L., Herndon, S. C., and Freedman, A.: Detection of nitrogen
dioxide by cavity attenuated phase shift spectroscopy, Anal. Chem.,
77, 724–728, 2005b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Kebabian et al.(2008)</label><mixed-citation>
Kebabian, P. L., Wood, E. C., Herndon, S. C., and Freedman, A.: A practical
alternative to chemiluminescence-based detection of nitrogen dioxide: Cavity
attenuated phase shift spectroscopy, Environ. Sci. Technol., 42,
6040–6045, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Kirchstetter et al.(1999)</label><mixed-citation>
Kirchstetter, T. W., Harley, R. A., Kreisberg, N. M., Stolzenburg, M. R., and
Hering, S. V.: On-road measurement of fine particle and nitrogen oxide
emissions from light-and heavy-duty motor vehicles, Atmos. Environ.,
33, 2955–2968, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Kraus(2005)</label><mixed-citation>
Kraus, S.: DOASIS A Framework Design for DOAS, Ph.D. thesis, Combined
Faculties for Mathematics and for Computer Science, University of Mannheim,
2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Kundu et al.(2019)</label><mixed-citation>
Kundu, S., Deming, B. L., Lew, M. M., Bottorff, B. P., Rickly, P., Stevens, P. S., Dusanter, S., Sklaveniti, S., Leonardis, T., Locoge, N., and Wood, E. C.: Peroxy radical measurements by ethane – nitric oxide chemical amplification and laser-induced fluorescence during the IRRONIC field campaign in a forest in Indiana, Atmos. Chem. Phys., 19, 9563–9579, <a href="https://doi.org/10.5194/acp-19-9563-2019" target="_blank">https://doi.org/10.5194/acp-19-9563-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Langridge et al.(2006)</label><mixed-citation>
Langridge, J. M., Ball, S. M., and Jones, R. L.: A compact broadband cavity
enhanced absorption spectrometer for detection of atmospheric NO<sub>2</sub> using
light emitting diodes, Analyst, 131, 916–922, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>LfU(2015)</label><mixed-citation>
LfU: Untersuchung der räumlichen Verteilung der NOx-Belastung im Umfeld von
vorhandenen, hochbelasteten Luftmessstationen, Abschlussbericht, Tech. Rep.,
Bayerisches Landesamt für Umwelt, 16–23, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>LfU(2019)</label><mixed-citation>
LfU, B.: Aktuelle Werte der bayerischen Luftmessstationen, available at:
<a href="https://www.lfu.bayern.de/luft/immissionsmessungen/messwerte/index.htm" target="_blank"/>,
last access: 29 November 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Massman(1998)</label><mixed-citation>
Massman, W.: A review of the molecular diffusivities of H<sub>2</sub>O, CO<sub>2</sub>, CH<sub>4</sub>, CO, O<sub>3</sub>,
SO<sub>2</sub>, NH<sub>3</sub>, N<sub>2</sub>O, NO, and NO<sub>2</sub> in air, O<sub>2</sub> and N<sub>2</sub> near STP, Atmos.
Environ., 32, 1111–1127, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Min et al.(2016)</label><mixed-citation>
Min, K.-E., Washenfelder, R. A., Dubé, W. P., Langford, A. O., Edwards,
P. M., Zarzana, K. J., Stutz, J., Lu, K., Rohrer, F., Zhang, Y., and Brown,
S. S.: A broadband cavity enhanced absorption spectrometer for aircraft
measurements of glyoxal, methylglyoxal, nitrous acid, nitrogen dioxide, and
water vapor, Atmos. Meas. Tech., 9, 423–440,
<a href="https://doi.org/10.5194/amt-9-423-2016" target="_blank">https://doi.org/10.5194/amt-9-423-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Ning et al.(2012)</label><mixed-citation>
Ning, Z., Wubulihairen, M., and Yang, F.: PM, NO<sub><i>x</i></sub> and butane emissions
from on-road vehicle fleets in Hong Kong and their implications on
emission control policy, Atmos. Environ., 61, 265–274,
<a href="https://doi.org/10.1016/j.atmosenv.2012.07.047" target="_blank">https://doi.org/10.1016/j.atmosenv.2012.07.047</a>,
2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Platt et al.(2009)</label><mixed-citation>
Platt, U., Meinen, J., Pöhler, D., and Leisner, T.: Broadband Cavity
Enhanced Differential Optical Absorption Spectroscopy (CE-DOAS) –
applicability and corrections, Atmos. Meas. Tech., 2,
713–723, <a href="https://doi.org/10.5194/amt-2-713-2009" target="_blank">https://doi.org/10.5194/amt-2-713-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Rakowska et al.(2014)</label><mixed-citation>
Rakowska, A., Wong, K. C., Townsend, T., Chan, K. L., Westerdahl, D., Ng, S.,
Močnik, G., Drinovec, L., and Ning, Z.: Impact of traffic volume and
composition on the air quality and pedestrian exposure in urban street
canyon, Atmos. Environ., 98, 260–270,
<a href="https://doi.org/10.1016/j.atmosenv.2014.08.073" target="_blank">https://doi.org/10.1016/j.atmosenv.2014.08.073</a>,
2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Rothman et al.(2003)</label><mixed-citation>
Rothman, L., Barbe, A., Benner, D. C., Brown, L., Camy-Peyret, C., Carleer, M.,
Chance, K., Clerbaux, C., Dana, V., Devi, V., Fayt, A., Flaud, J.-M.,
Gamache, R., Goldman, A., Jacquemart, D., Jucks, K., Lafferty, W., Mandin,
J.-Y., Massie, S., Nemtchinov, V., Newnham, D., Perrin, A., Rinsland, C.,
Schroeder, J., Smith, K., Smith, M., Tang, K., Toth, R., Auwera, J. V.,
Varanasi, P., and Yoshino, K.: The HITRAN molecular spectroscopic database:
edition of 2000 including updates through 2001, J. Quant.
Spectrosc. Ra., 82, 5–44,
<a href="https://doi.org/10.1016/S0022-4073(03)00146-8" target="_blank">https://doi.org/10.1016/S0022-4073(03)00146-8</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Thalman and Volkamer(2010)</label><mixed-citation>
Thalman, R. and Volkamer, R.: Inherent calibration of a blue LED-CE-DOAS
instrument to measure iodine oxide, glyoxal, methyl glyoxal, nitrogen
dioxide, water vapour and aerosol extinction in open cavity mode, Atmos.
Meas. Tech., 3, 1797–1814, <a href="https://doi.org/10.5194/amt-3-1797-2010" target="_blank">https://doi.org/10.5194/amt-3-1797-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>UBA(2017)</label><mixed-citation>
UBA: Air quality 2016 (Preliminary Evaluation), Tech. rep., Umweltbundesamt
(German Environment Agency),   2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>Uhrner et al.(2007)</label><mixed-citation>
Uhrner, U., von Löwis, S., Vehkamäki, H., Wehner, B., Bräsel, S.,
Hermann, M., Stratmann, F., Kulmala, M., and Wiedensohler, A.: Dilution and
aerosol dynamics within a diesel car exhaust plume-CFD simulations of
on-road measurement conditions, Atmos. Environ., 41, 7440–7461,
<a href="https://doi.org/10.1016/j.atmosenv.2007.05.057" target="_blank">https://doi.org/10.1016/j.atmosenv.2007.05.057</a>,
2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>Vandaele et al.(2002)</label><mixed-citation>
Vandaele, A. C., Hermans, C., Fally, S., Carleer, M., Colin, R., Mérienne,
M.-F., Jenouvrier, A., and Coquart, B.: High-resolution Fourier transform
measurement of the NO<sub>2</sub> visible and near-infrared absorption cross
sections: Temperature and pressure effects, J. Geophys. Res.-Atmos., 107, 4348, <a href="https://doi.org/10.1029/2001JD000971" target="_blank">https://doi.org/10.1029/2001JD000971</a>, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>Venables et al.(2006)</label><mixed-citation>
Venables, D. S., Gherman, T., Orphal, J., Wenger, J. C., and Ruth, A. A.: High
sensitivity in situ monitoring of NO<sub>3</sub> in an atmospheric simulation
chamber using incoherent broadband cavity-enhanced absorption spectroscopy,
Environ. Sci. Technol., 40, 6758–6763, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>Villena et al.(2012)</label><mixed-citation>
Villena, G., Bejan, I., Kurtenbach, R., Wiesen, P., and Kleffmann, J.:
Interferences of commercial NO<sub>2</sub> instruments in the urban atmosphere and
in a smog chamber, Atmos. Meas. Tech., 5, 149–159,
<a href="https://doi.org/10.5194/amt-5-149-2012" target="_blank">https://doi.org/10.5194/amt-5-149-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>Vogt et al.(2003)</label><mixed-citation>
Vogt, R., Scheer, V., Casati, R., and Benter, T.: On-Road Measurement of
Particle Emission in the Exhaust Plume of a Diesel Passenger Car,
Environ. Sci. Technol., 37, 4070–4076, <a href="https://doi.org/10.1021/es0300315" target="_blank">https://doi.org/10.1021/es0300315</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>Volkamer et al.(2005)</label><mixed-citation>
Volkamer, R., Spietz, P., Burrows, J., and Platt, U.: High-resolution
absorption cross-section of glyoxal in the UV–VIS and IR spectral ranges,
J. Photoch. Photobio. A, 172, 35–46,
<a href="https://doi.org/10.1016/j.jphotochem.2004.11.011" target="_blank">https://doi.org/10.1016/j.jphotochem.2004.11.011</a>,
2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>Washenfelder et al.(2008)</label><mixed-citation>
Washenfelder, R. A., Langford, A. O., Fuchs, H., and Brown, S. S.: Measurement
of glyoxal using an incoherent broadband cavity enhanced absorption
spectrometer, Atmos. Chem. Phys., 8, 7779–7793,
<a href="https://doi.org/10.5194/acp-8-7779-2008" target="_blank">https://doi.org/10.5194/acp-8-7779-2008</a>, 2008.

</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>Wesely and Hicks(2000)</label><mixed-citation>
Wesely, M. and Hicks, B.: A review of the current status of knowledge on dry
deposition, Atmos. Environ., 34, 2261–2282, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>Westerdahl et al.(2005)</label><mixed-citation>
Westerdahl, D., Fruin, S., Sax, T., Fine, P. M., and Sioutas, C.: Mobile
platform measurements of ultrafine particles and associated pollutant
concentrations on freeways and residential streets in Los Angeles,
Atmos. Environ., 39, 3597–3610,
<a href="https://doi.org/10.1016/j.atmosenv.2005.02.034" target="_blank">https://doi.org/10.1016/j.atmosenv.2005.02.034</a>,
2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>Xie et al.(2019)</label><mixed-citation>
Xie, C., Xu, W., Wang, J., Wang, Q., Liu, D., Tang, G., Chen, P., Du, W., Zhao,
J., Zhang, Y., Zhou, W., Han, T., Bian, Q., Li, J., Fu, P., Wang, Z., Ge, X.,
Allan, J., Coe, H., and Sun, Y.: Vertical characterization of aerosol optical
properties and brown carbon in winter in urban Beijing, China, Atmos.
Chem. Phys., 19, 165–179, <a href="https://doi.org/10.5194/acp-19-165-2019" target="_blank">https://doi.org/10.5194/acp-19-165-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>Xie et al.(2015)</label><mixed-citation>
Xie, Y., Zhao, B., Zhang, L., and Luo, R.: Spatiotemporal variations of PM<sub>2.5</sub>
and PM<sub>10</sub> concentrations between 31 Chinese cities and their relationships
with SO<sub>2</sub>, NO<sub>2</sub>, CO and O<sub>3</sub>, Particuology, 20, 141–149, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>Yoo et al.(2014)</label><mixed-citation>
Yoo, J.-M., Lee, Y.-R., Kim, D., Jeong, M.-J., Stockwell, W. R., Kundu, P. K.,
Oh, S.-M., Shin, D.-B., and Lee, S.-J.: New indices for wet scavenging of air
pollutants (O<sub>3</sub>, CO, NO<sub>2</sub>, SO<sub>2</sub>, and PM<sub>10</sub>) by summertime rain, Atmos.
Environ., 82, 226–237, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>Zhu et al.(2018)</label><mixed-citation>
Zhu, Y., Chan, K. L., Lam, Y. F., Horbanski, M., Pöhler, D., Boll, J.,
Lipkowitsch, I., Ye, S., and Wenig, M.: Analysis of spatial and temporal
patterns of on-road NO<sub>2</sub> concentrations in Hong Kong, Atmos.
Meas. Tech., 11, 6719–6734, <a href="https://doi.org/10.5194/amt-11-6719-2018" target="_blank">https://doi.org/10.5194/amt-11-6719-2018</a>, 2018.
</mixed-citation></ref-html>--></article>
